molly-guard binary package in Ubuntu Kinetic s390x

 The package installs a shell script that overrides the existing
 shutdown/reboot/halt/poweroff/coldreboot/pm-hibernate/pm-suspend* commands
 and first runs a set of scripts, which all have to exit successfully,
 before molly-guard invokes the real command.
 .
 One of the scripts checks for existing SSH sessions. If any of the four
 commands are called interactively over an SSH session, the shell script
 prompts you to enter the name of the host you wish to shut down. This should
 adequately prevent you from accidental shutdowns and reboots.
 .
 molly-guard diverts the real binaries to /lib/molly-guard/. You can bypass
 molly-guard by running those binaries directly.

Publishing history

Date Status Target Pocket Component Section Priority Phased updates Version
  2022-04-26 10:05:31 UTC Published Ubuntu Kinetic s390x release universe admin Extra 0.7.2
  • Published
  • Copied from ubuntu eoan-proposed amd64 in Primary Archive for Ubuntu